Detex Electric Integration Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Sécurité Detex Electric Integration. Detex Electric Integration User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 1
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
®
Jewelers (Small) Screwdriver
Tools Required
Detex Corporation, 302 Detex Drive, New Braunfels, Texas 78130-3045
(830)629-2900 / 1-800-729-3839 / Fax (830)620-6711
E-MAIL: [email protected] INTERNET: www.detex.com
104875 December 14, 2011
INSTALLATION INSTRUCTIONS FOR
ADVANTEX / VALUE SERIES RIM EI PRODUCT
Owner's Copy
Authorized Access switch is activated by outside lever trim
Activation of the pushpad will transfer switch contact.
LBM (latch bolt monitor) in series with pushpad switch.
KEY SWITCH common 12 to 24 volts DC, 500ma
GROUND (-) common to Green, Red, and siren
GROUND (-) common to Green, Red, and siren
PushPad/LBM monitors the pushpad and the deadlocking actuator in the latchbolt.
move the appropriate jumper on the circuit board.
To select Open or Closed switch orientation,
GND
GND
*JUMPER
EI CIRCUIT SCHEMATIC
Theory of Operation:
Jumpers
*
GREEN LED (+) 12 to 24 volts DC, 10ma max
KEY SWITCH normally open contact
KEY SWITCH normally closed contact
SIREN (+) 12 to 24 volts DC, 110ma max
RED LED (+) 12 to 24 volts DC, 10ma max
Terminal
8
11
12
10
9
3, 4
5
6
*
7
1, 2
No.
*
Red wire
Comments
SIREN
GREEN
NO
NC
KEY
NC
GND
RED
*JUMPER
NO
*
PushPad/LBM
Switch
Switch
Authorized Access
CUSTOMER WIRING
Key Switch
12 (-)
4 COMMON
10 OPEN
9 COMMON
7 (+) SIREN
11 CLOSED
2 COMMON
1 *OPEN/CLOSED
3 *OPEN/CLOSED
5 (+) GREEN LED
6 (+) RED LED
8 (-)
Call customer service for replacement part number
EI Fillerplate Subassembly p/n 101783-X
Rim EI - Electric Integration
Dwg #: 101379 Advantex (SS)
104600 Advantex (AL)
101800 Value Series
&
Door Closed - Deadlocking actuator activates PushPad/LBM (Latch Bolt Monitoring) Switch. Authorized Access Switch is not affected.
Door Closed - Depressing PushPad changes the state of the PushPad/LBM Switch. Authorized Access Switch is not affected.
Door Closed - Authorized (Auth) Access Switch is activated by operating outside trim. As the latchbolt begins to retract, the
PushPad/LBM Switch is also activated.
EI PWA
p/n 101782
PRECAUTIONARY NOTE:
Be careful when installing filler plate assembly not to damage ribbon cable.
104875 Page 1
Vue de la page 0
1

Résumé du contenu

Page 1 - Owner's Copy

®Jewelers (Small) ScrewdriverTools RequiredDetex Corporation, 302 Detex Drive, New Braunfels, Texas 78130-3045(830)629-2900 / 1-800-729-3839 /

Commentaires sur ces manuels

Pas de commentaire