DETEX INS2049SC PAGE 1
INSTALLATION INSTRUCTIONS FOR MAGNETIC SWITCH MS-2049SC
Detex Corporation, 302 Detex Drive, New Braunfels, Texas 78130 (830)629-2900 1-800-729-3839 FAX (830)620-6711
E-Mail: [email protected] Internet: www.detex.com
INS-2049SC April 20, 2007
ELECTRICAL SPECIFICATIONS
SWITCH (SPDT)
MAXIMUM CONTACT RATING;
500 mA at 24V
BLK COM
RED OPEN
WHT CLOSED
WHT
RED
BLK
SHOWN DOOR SECURE
The MS-2049SC is designed for use with thin-wall con-
duit. If the product is to be installed on the latch side of
the door, allowance must be made for the space required
by the conduit. Position the template near the center of
the door. To bring the conduit in from the hinge side, the
adapter can be reversed.
Contacts should be installed so that the door cannot be
opened more than 2 inches without causing an alarm
condition.
Mark the hole centers and drill the holes as required on
the template.
Install the bracket on the door with three screws,
#10 x 1" at head, thread-forming.
Position the magnet on the bracket and slip the cover
up into position. Fasten these parts together with two
screws, #8-32 x 3/4", as shown.
Screw the connector into the adapter.
Assemble the adapter, switch cover and switch and slip
the clip over the adapter web and cover ange, as shown.
Connect the wires from the monitoring device to the
switch wires and pull the slack back through the conduit.
Run two #10 x 1-1/2" sheet metal screws through the
switch, switch cover and adapter. Fasten tightly to frame.
CAUTION - DO NOT OVERTIGHTEN!
Insert the conduit into the nut on the connector and
tighten the nut.
NOTE: Plastic anchors (part #101129-1) are provided
for concrete reinforced frames. In this case (2) 1/4" dia.
holes are drilled using the same template. Tap anchors
lightly into holes until ush with frame. Assemble switch
as stated above.
MS-2079
CONNECTOR
CLIP
MS-2080
ADAPTER
MS-2078M
COVER
MS-2075
SWITCH
MS-2058
SCREW (2)
PP-5212-72
ON FRAME
ON DOOR
SCREW (2)
PP-5377-112
MAGNET
MS-2057
BRACKET
MS-2076M
SCREW (3)
PP-5212-68
COVER
MS-2062